Sol-Ark Parameters

Inverter Set: 1, 3, 4 Up

2, 5, 6 down


Open loop (without the communication cable) for Stack'd 

Float V: 52.2V
Absorption V: 52.2V
Equalization V: 52 2V
Batt Capacity: 100Ah per module
Batt A Charge: 100A per module, max. Limit 300A per controller
Batt A Discharge: 100A per module, max. Limit 300A per controller

Shutdown: 48.6V
Low batt: 48.9V
Restart: 51V

Batt empty: 43V


Closed Loop (with the communication cable) Parameters in image below: